<p>Hi Carrie,</p>
<p></p>
<p>If you use the AFG in basic mode, you can set it to output a Burst and to trigger that burst externally, then you can configure the trigger delay and, from my testing, it should be very stable.</p>
<p></p>
<p>If your trigger delay isn't stable with this setup, it's probably because of the Siglent function generator that has an unstable trigger output delay (hence why they said it was difficult to synchronize). To fix this you could try triggering the AFG off your output signal instead of the trigger or reverting the setup and having the AFG be the master and the Siglent the slave.</p>